Quantcast
Channel: SCN: Message List
Viewing all 8902 articles
Browse latest View live

Re: Can I change the universe using Data Manager

$
0
0

Hello Arijit,

 

Thanks for the response. Do I open any report by browsing through the system? Is that how a report is can be opened in deski?


Re: SAP ERP System - slow system

$
0
0

Hello Samid,

 

 

 

Before any upgrade,kernel patch etc, Always take backup of  parameters from table TUO2

Freight in Info record Vs Frieight on PO header level

$
0
0

Hi,

 

I have a requirement..

So, far we used Freight only at Item level in PO. FRA1/FRB1/FRC1 used for this.. They are manual conditions per the pricing procedure.

 

Now, we need freight condition available on the PO header level as well..

For this, FRA2/FRB2/FRC2 has been maintained as Group and Header level condition in this respective Condition type config and included in the pricing procedure as manual conditions.

 

Some business units even maintain Freight in the Info records.

Requirement is that, in case of raising POs for those materials that have an info record and freight maintained as a condition, the header condition should over ride the info record freight condition.

 

Possible?

 

Regards,

SS

Re: How to Block Sales in Multiple Currency at Row Level

$
0
0

Hi,

 

Yes possible by SPTN. Try this:

 

 

IF @transaction_type in ('A') AND (@OBJECT_TYPE='17')

 

BEGIN

 

IF  exists (SELECT t0.docentry FROM ORDR T0  INNER JOIN RDR1 T1 ON
T0.DocEntry = T1.DocEntry WHERE T0.[DocCur] = T1.[Currency] and
t0.docentry =  @list_of_cols_val_tab_del )

 

Begin

 

SET @error = 123

 

SET @error_message = 'Row currency is not same as document
currency'

 

End

End

 

Thanks & Regards,

Nagarajan

Re: The SAP ECC server node not showing in SAPMMC. (sapstartsrv.exe showing error)

$
0
0

Hi Amber

 

Its not require to do any thing. if possible do full restart the system once check the service starting automatic or not?

 

Regards

Sriram

Decision Step in web dynpro screen.

$
0
0

Hi All,

 

I have requirement of when double clicks on the work item the custom webdynpro screen needs to open and in the screen i have to provide approve/reject. So that user can edit and approve/reject the specification. If user clicks the approve how to handle the workflow.

 

Currently i have provided webdynpro screen as attachment in work item. The work item is user decision step once clicks on the attachment it will be routed to webdynpro screen. The problem here is users need to do more clicks one for to open the work item and one for to open the webdynpro screen and one for the save data and one for the come back to work item after that needs click on approve/reject.

 

Explanation:

In the Work item screen (Workflow), I am giving some link where I can access a webdynpro screen.

Here I have created a Tcode for the Webdynpro screen and I am calling the Tcode by that link which I placed under the Workitem screen.

 

Now, if user makes respective changes in the webdynpro screen hitting that link, he/she has to get back to the previous screen. (ie. Workitem screen).

 

Please suggest how to work on this.

 

Thanks

Sreekar.R

Re: Change log at SAP Business One

$
0
0

Hi Nagarajan,

 

I have run you query, but the result is 0 row.

 

Thanks,

Dong Pham Nhat

Schedule line proposed quantity for dependent material is more then required

$
0
0

Hi,

 

I have a BOM which consist of 4 subcontacting material as items.

 

When I run MRP, it creates schedule lines for the Header item, and all the dependent requirements are generated for child items.

 

However, the MRP proposed quantity of the child item is more than it should be required.

 

I have done manual calculation as well.

 

 

Product X

 

Child 1       MRP proposed -  144       Actual cal culation through BOM    ---  111

Child 2

Child 3

Child 4

 

What could be the possibilities. I have checked for scrap % in bom items, but its not maintained. Is LOT size calculation is the reason for this variance?


Re: inventory valuation to be actual

$
0
0

Hi,

 

Please close this thread if you got answer by marking correct/helpful answer.

 

Thanks & Regards,

Nagarajan

Re: In Inventory Transfer Request Screen, From Warehouse Fadeout

$
0
0

Hi,

 

Have you checked above SPTN?

 

Thanks & Regards,

Nagarajan

Re: Nota 1975152

$
0
0

Que tal! yo no puedo ver la nota 1982036, me aparece un mensaje indicando que la nota no ha sido liberada, podrían por favor pegar la información de la nota?

Re: Schema error in NW 7.3

$
0
0

Hi Kamil,

 

I tried to create a database in SQL. Its created. I don't know what level of permission required to create a folder or mdf files in E drive. Please let me know. My user has the admin rights.

I tried to create folder manually but even though it cant able to create the mdf file.

 

Please let me know the solution?

 

Regards

R.Prakash

Re: Drag and drop function in web dynpro

$
0
0

test.jpg

 

This is my setting of drag source and the tag is same as the drop target's one.

When I try to drag, it doesn't show and symbol or icon, just the same curser.

DN mvt 651

$
0
0

Hi Experts,

 

For some DNs, mvt is 651 (GD ret.del returns).

 

May I ask how to link DNs with mvt 651 to the DNs with mvt 601?

 

BR,

King

Re: sapmmc stays yellow when starting server

$
0
0

Hi,

 

Normally this kind of issue you will get in sapmmc .After reboot the system process are getting started still your the error is getting kindly Activate the 3 GB boot option according toMicrosoft KB article 283037(Snote110172).


Re: Schedule line proposed quantity for dependent material is more then required

$
0
0

Hi,

 

  1. Check the quantity maintained in BOM
  2. Check if any fixed lot size is used. In case o fixed lot size irrespective of the requirement qty poposals will be generated for fixed qty.

 

Thanks & Regards,

Ramagiri

Re: CUP 5.3 USER CREATE-Password logon no longer possible - too many failed attempts

$
0
0

Hi Mithuna

 

Have you checked the system user against your JCo connector to see if the account is locked in the satellite system?

 

 

Regards

Colleen

Re: OUTPUT Type are determined but not added into header

$
0
0

Hi Rodrigo,

 

Please try setting up the condition records properly. Iessa has already suggested the path to maintain the output condition records. When you double click on the codtion records, you will reach a screen where you can provide details of the output device. also, please make sure that you check the 'print immediately' checkbox. However, the print immediately option would not have any direct bearing on the condition record being picked automatically. It only tells the system whether the print is to be generated immediately or spooled for later printing.

 

I also suggest that you get your basis team to check your printer settings. I have experienced such issues in the past and they were related to the output device.

 

Hope this helps.

 

Regards,

 

Sumita Mittra

Re: RS_CORR_INSERT: bypass DEVELOPER_CHECK, possible?

$
0
0

Ok, I feel I should clarify a bit since I would think the same upon this request.

 

First, the program allows only to modify fixed values, not other attributes such as lenght or type.

This reduces tremendously the risks, narrowing them to the deletion or description change of values already used in table records or referenced to in programs, and this is clearfully explained upon running the program with a big warning.

 

Secondly, the use case is for a specific standard domain, which was modified (repaired) years ago to add fixed values, and is used almost as a table nowadays. I receive monthly requests to add or change values on it, so I though why the heck couldn't the functional analyst update the values himself as he does for regular customizing tables (that's another risk reducer, not ANY user would run the program). It won't even reach quality client, it is to be used in dev only and domain changes to be transported as usual.

 

I could even restrict the program to only that specific domain, or disallow deletion of values, but I wanted to keep it pretty generic should a similar need arise later.

 

Now, to the problem at hand, the only workaround I thought of so far is exactly the same you suggest Jamie (create and use an RFC enabled wrapper of RS_CORR_INSERT with my username entered in the destination), and it seems I'll end up trying just that. Any other ideas are welcomed.

 

I could always program an enhancement at the beginning of DEVELOPER_CHECK to leave if my program is in the call stack, but that seems a bit extreme

 

Regards

Re: Empty File handling and raise alert.

$
0
0

Thanks for suggestion's. Just wanted to get some more clarification on alert part.

When you say throw exception if size is not equals to 0, then how exactly we can raise the alerts. One way could be not defining any receiver for that condition, but in this case the exception would always say "InterfaceDetermination did not yield any actual interface".

Can you please elaborate on exception and alert part?

 

Thanks,

Vertika

Viewing all 8902 articles