Maintenance plan creation
Hi All, We have created maintenance items using transaction code IP04. Now with reference to this we want to create the new maintenance plan. When we go to transaction code IP01, it asks us to maintain...
View ArticleBOFC Migration from Oracle Database to MS-SQL
Hello All, Please help to share your expertise or relevant SAP documents in performing the BOFC Heterogeneous Migration i.e from Oracle DB to MSSQL DB.1. How to we perform of Oracle DB2. What are...
View ArticleRe: Storage process step OB02 is not assigned to storage process
Thanks Suraj , it was due to incorrect WOCR.
View ArticleRe: Problem with Absence WT split .
Hi Nalini, Have you delimited info type 0008? Ur's Mohan
View ArticleRe: doubts in narrow casting
Hi,*call method o_super->m4. "throws syntax error.but when i change this to m4 in brackets:call method o_super->('m4'). "works fine WHY!!!!!! (atleast no syntax error)but the prog...
View ArticleRe: Production order : Determination of source inventory failed
Hi, Problem might be due to insufficient inventory Thanks ..
View ArticleHow to join two internal table rows in alternative manner into one internal...
How to join two internal table rows in alternative manner into one internal table? two internal tables are suppose itab1 & itab 2Header 1Header 2Header 3abcdefghiHeader 1Header 2Header...
View ArticleRe: Solman_Workcenter Error on Fast Display Message
Hi, Kindly share parameter value for abap/heap_area_total.If possible try to adjust memory settings . Regards,Gaurav
View ArticleLockbox and Special G/L
Hello all, Is there a way to have AR Lockbox configured to post customer on-accounts to PK 19 and a special g/l that has been designated for customer on- accounts? In OBAX there is only a posting key...
View ArticleRe: open a dashboard through mobile?
With latest versions of dashboards, we can now create mobile compatible HTML5 dashboards. Auto refresh before or after components are loaded can be configured. But keep in mind that not all components...
View ArticleRe: Passing select option parameters from one program to another
Hi, Check this example,Filling the Selection Screen of a Called Program (SAP Library - ABAP Programming (BC-ABA)) Regards,Nitin
View ArticleRe: Stock transport Order - how to populate Storage location LGOBE field?
Hi, You may maintain the storage location in the STO itself, so that the same will be populated in MIGO. If required, maintain the storage location in the personal settings in ME21N for the user, as...
View ArticleBring in Min/Max values from ECC to DC parameter details.
With ME 6.1, inspection characteristics can be sent from ECC and be populated as the Data Collection parameters. But is there a way to bring in Min/Max values and populate them in the DC Parameter...
View ArticleRe: SLD change
I have an update about the content sync. It appears that Wolf Hengevoss's video demo (which is the only documentation I've found on this topic) assumes that you are using SLD's on both ends of the...
View ArticleRe: GRC PC 10.0 - Offline PDF Processing - Submit Action not being processed
But how do you configure the inbound parameters in GRC, and how do you configure response of the offline test plan from the user?
View ArticleRe: Create material with two alternative raw materials
Hi,In addition to Mr. Anupam sharma's reply..two alternate BOM's can be created with same usage only.in your case usage 1... no need to use different usage for each BOM... ThanksKumar
View ArticleTransfer configuration data to subitems in quote in CRM
Hi All, We are using the method CHANGE_FIELDS_AFTER_CONFof the BADI CRM_CONFIG_BADI to transfer values from configurator to Quote. Only the main items are transferred. Can anyone suggest how to...
View Article